For a standard 4x2 floor truss meaning warren style webs with 30 inch panels with double cut webs the maximum round duct in the end panel is 5 625.
Floor trusses hvac chase.
Hvac chases are typically 24 wide and as tall as the height between the top and bottom chords will allow.
I was annoyed that the truss company had not included a clear path for running metal ducts.
See sbca s ttb floor truss fact sheet.
Stuart lewis from alpine engineered products tells us.
Design criteria for the 4 x 2 floor system.
Still commonly used is the panned floor joist.
This also reduces the need and cost for extra bearing posts beams and footings.
Hvac chases or duct runs may be designed into floor trusses to allow for plumbing and or heating and air conditioning ducts to be installed in the floor.
Floor trusses can span farther between bearing points than i joists allowing for larger open rooms.
Using floor joists as return ducts by panning can cause leakage because negative pressure in the cavity will draw air from the outside into the cavity through the construction joints of the rim area at the end of the joist cavity.
Open joist is a revolutionary open web all wood floor truss engineered with superior strength and load carrying capabilities.
Maximum span to depth ratio of 1 to 20 example 14 truss should not exceed 23 4 span spacing may be adjusted to accommodate longer spans maximum 24 duct chase on flat wise trusses minimum duct chase offset from the bearing is of the span.
There simply wasn t a way to get from the mechanical room to the other end of each floor using metal.
Floor trusses have built in openings which can be used to install hvac ductwork plumbing lines and electrical wiring.
I specified open web trusses for my new house in part to simplify the installation of mechanical systems.
Ducts in a special roof truss.
Alpine engineered products now itw referred these to floor trusses as system42 trusses.
Hvac chases in floor trusses hvac chase.
Open web design leaves plenty of room for mechanical systems hvac plumbing electrical to be installed within the floor frame.
It s possible to order special roof trusses called plenum trusses designed to accommodate a duct chase near the attic floor.
Are there charts illustrating allowable hvac duct sizes that can fit between truss chords for various truss depths.
Most truss manufacturers can produce custom plenum trusses that include an integral duct chase.